Home     GE Turbine Control     GE Mark VI     DS200DTBAG1A

ProductS

DS200DTBAG1A

TERM. DIGITAL CONT
Product DESCRIPTION
Part Number
DS200DTBAG1A
Manufacturer
General Electric
Country of Manufacture
As Per GE Manufacturing Policy
Series
Mark V
Function
Module
Availability
In Stock
services we provide
Purchase Icon
Testing & Repair
Repair and Testing of circuit boards to diagnose ensure functionality to maintain current inventory and retain obsolete circuit boards/modules.
Exchange Icon
Training
Controls including HMI Training for Engineers, Technicians and Operators with wide variety of practical equipment including Management and Health & Safety.
Repair Icon
Purchase
You upgrade equipment and we purchase your surplus inventory to maximize the value of unused or end of life assets.
TECHNICAL SPECIFICATIONS FOR GE - DS200DTBAG1A

DS200DTBAG1A is a Digital Contact Terminal Board manufactured by General Electric as part of the Mark V LM Series used in gas turbine control management systems. Q11, Q21, and Q51 are the locations of the Contact Input Termination Module (DTBA). The first 46 contact inputs in the same digital core are connected to TCDA through DTBA. To enable fail-safe contact input functionality, the inputs can be configured in the TCDA IO Configuration to invert the contact sense. JY receives 125 V dc power from the DTBA board. The TB2 terminal board allows the excitation voltage for contact inputs DTBA and DTBB terminal boards in the digital cores to be 125 V dc from core or 24 V dc from core. Implementation of the desired contact input excitation option is done at the factory.

  • To provide a fuse isolated and current limited interrogation voltage for the contact inputs, the Mark V LM controller draws either 125 V dc or 24 V dc from the power distribution core. By cutting off the interrogation voltage, jumpers on the DTBA and DTBB terminal boards can be utilized to isolate field grounds.
  • They are connected in eight-contact input groupings. Changes to these jumpers should only be made when the turbine is not in operation. On the TCDA board, which is in Location 1 of the digital I/O core, each contact input is optically isolated.
  • The CPU on the TCDA board assigns a time stamp to each contact input within 1 millisecond of a status change. Whenever a contact input's state changes, the operator interface printer can record the time stamp if the input is chosen for logging. If the contact input circuit fails, diagnostic checks constantly run and sound an alert.
featured products