Home     GE Turbine Control     GE Mark VI     DS3800HCIB

ProductS

DS3800HCIB

PDP II/CSH I/F BD
Product DESCRIPTION
Part Number
DS3800HCIB
Manufacturer
General Electric
Country of Manufacture
As Per GE Manufacturing Policy
Series
Mark VI/VIe
Function
Module
Availability
In Stock
services we provide
Purchase Icon
Testing & Repair
Repair and Testing of circuit boards to diagnose ensure functionality to maintain current inventory and retain obsolete circuit boards/modules.
Exchange Icon
Training
Controls including HMI Training for Engineers, Technicians and Operators with wide variety of practical equipment including Management and Health & Safety.
Repair Icon
Purchase
You upgrade equipment and we purchase your surplus inventory to maximize the value of unused or end of life assets.
TECHNICAL SPECIFICATIONS FOR GE - DS3800HCIB

DS3800HCIB is a turbine control board developed by GE. It is a part of Mark IV control system. As part of the Mark IV control system, the board integrates seamlessly with other control components and subsystems, forming a comprehensive control and monitoring solution for turbine-driven systems. With its robust design and state-of-the-art technology, the component offers a wide range of features that contribute to the optimal performance of the turbine system. It enables precise control over various turbine parameters, such as speed, temperature, pressure, and flow. It continuously monitors these parameters to ensure that the turbine operates within safe and efficient operating limits.

Features

  • Modular Connector and Retention Levers: The board is equipped with a modular connector that enables seamless connection to a compatible drive. Additionally, retention levers are provided to securely hold the board in place within the drive. These levers ensure a stable and reliable connection, preventing accidental dislodging.
  • Jumper and Indicator LED: The board is populated with one jumper, which allows for configuration or customization of specific settings on the board. Additionally, there is an amber indicator LED that provides visual feedback or status indication.
  • 20-pin and 50-pin Connectors: The board features a 20-pin connector and a 50-pin connector. These connectors serve as interfaces for connecting various external devices or components to the board. The operator has convenient access to these connectors when the board is mounted in the rack, facilitating easy connection and disconnection of cables.
  • Capacitors: The board includes numerous capacitors, which are passive electronic components used to store and release electrical energy. Capacitors play a vital role in smoothing out voltage fluctuations and stabilizing the power supply within the control system.
  • Ribbon Cable Considerations: Before installing the ribbon cables, there are certain factors to consider. It is important to ensure proper routing of the cables to avoid obstructing airflow within the drive. Incorrect cable placement can restrict the circulation of air and potentially impact the cooling efficiency of the system. Proper cable management and routing are essential for maintaining optimal airflow and preventing overheating issues.

Operating Interface

  • Multiple Displays: The operating interface includes multiple displays that provide real-time information about the system's logic, switches, internal components, output relay status, sensors, and actuators. These displays offer a holistic view of the turbine control system, allowing operators to monitor various parameters and statuses simultaneously.
  • Logic and Parameter Presentation: The displays present detailed information regarding the logic of the control system. This includes the values of turbine-mounted switches, internal logic elements, and the status of output relays. Furthermore, the interface also presents the values of sensors and actuators, enabling operators to monitor their performance and ensure optimal functionality.
  • Display Menu: The operating interface incorporates a menu system that allows users to select specific pages or screens to view the desired information. The menu provides easy navigation and access to the various display options available. Users can choose specific pages to focus on different aspects of the control system, such as alarms, status overviews, or specific control parameters.
  • Copying Displays: To facilitate documentation or record-keeping, the operating interface includes a roll-out printer feature. By pressing the designated "Copy" button, users can easily generate printed copies of the displayed information. This feature allows for convenient archiving or sharing of critical data and system status reports.
  • Display Variety: The operating interface boasts an extensive library of approximately 200 pages or screens. While it is not possible to describe all of them in detail, the interface offers a diverse range of display options catering to various aspects of the control system. These pages can include detailed status information, control parameters, graphical representations, alarms, and troubleshooting data.
  • Enhanced Accessibility and Troubleshooting: One significant advantage of the operating interface is that it reduces the need for users to physically access the Mark IV panel for adjustments or fault troubleshooting. The comprehensive displays provide detailed information, allowing operators to identify issues, monitor system performance, and make informed decisions without requiring direct access to the control panel. This enhances convenience, safety, and efficiency during routine operations and maintenance tasks.
featured products