Home     GE Turbine Control     GE Mark VI     IS210TRPGH1B

ProductS

IS210TRPGH1B

GT PRIMARY TRIP DIN RAIL MODUL
Product DESCRIPTION
Part Number
IS210TRPGH1B
Manufacturer
General Electric
Country of Manufacture
As Per GE Manufacturing Policy
Series
Mark VI/VIe
Function
Module
Availability
In Stock
services we provide
Purchase Icon
Testing & Repair
Repair and Testing of circuit boards to diagnose ensure functionality to maintain current inventory and retain obsolete circuit boards/modules.
Exchange Icon
Training
Controls including HMI Training for Engineers, Technicians and Operators with wide variety of practical equipment including Management and Health & Safety.
Repair Icon
Purchase
You upgrade equipment and we purchase your surplus inventory to maximize the value of unused or end of life assets.
TECHNICAL SPECIFICATIONS FOR GE - IS210TRPGH1B

IS210TRPGH1B is a Gas Turbine Primary Trip Terminal Board manufactured and designed by General Electric as part of the Mark VIe Series used in GE Distributed Control Systems. The TRPG terminal board is controlled by the I/O controller. TRPG contains nine magnetic relays in three voting circuits to interface with three trip solenoids, known as Electrical Trip Devices (ETD). The TRPG works in conjunction with the TREG to form the primary and emergency sides of the interface to the ETDs. TRPG also accommodates inputs from eight Geiger Mueller flame detectors for gas turbine applications. The H1A version for TMR applications has three voting relays per trip solenoid. The H1A and H1B versions include three voting relays built into each trip solenoid for TMR applications. The PTUR packs on TTURH1C control TRPG in Mark VIe systems. The D-type connectors on TTURH1C, which is connected to TRPG, accept the I/O packs as an input. Systems using simplex and TMR are both supported.

INSTALLATION:

The flame detectors (if utilized) are attached directly to the second terminal block, while the three trip solenoids are wired to the first I/O terminal block. The flame detectors are linked with power to J3, J4, and J5. J1 receives 125 V dc power for the trip solenoids, and J2 supplies power to the TREG board.

OPERATION:

The main protection solenoids are tripped by the main protection relays on TRPG, which are controlled by the I/O board. In TMR applications, a relay ladder logic two-out-of-three voting circuit is used to vote the three inputs in hardware. The I/O board keeps track of supply voltages for diagnostic purposes and tracks the current flow in its relay driver control line to determine whether to electrify or de-electrify the relay coil contact status. The diagnostics check each normally closed contact from a relay on the TRPG board to make sure it is functioning properly.

The controller transmits the primary overspeed trip, which is subsequently transmitted to the I/O pack or board and finally to the TRPG terminal board. Together with the TREG board, which is managed by the VPRO emergency overspeed system, TRPG functions. The TRPG/TREG combination may drive three ETDs.